设为首页 加入收藏

TOP

枸橼酸钠注射液 Citra-Lock 46.7% Kath-Blocklsg. Ampullen
2014-04-22 12:02:34 来源: 作者: 【 】 浏览:3452次 评论:0

Citra-Lock™ 46,7%

the effective concentrationsCL467 vial

Using Citra-Lock™ 46,7% :

  • improves overall patency rates
  • reduces catheter-related infections
  • reduces major bleeding for both tunneled an untunneld Central Venous Catheters (CVC) 

Anti Microbial

 

cl3046 afb 1

Superior antimicrobial activity of trisodium citrate over heparin for catheter locking, Marcel C. Weijmer et al, Nephrol Dial Transport (2002) 17: 2189-2195

 

cl3046 afb 2

Since the introduction of Citra-Lock™ (46,7%) to the renal departmant of St.Bard's renal unit (Royal London Hospital) has proven record in managing MRSA.

The number of MRSA infections has fallen from 2,27/1000 patiens catheter days to 1,36/1000 patiens catheter days.

Citra-Lock™ intervention provides significant benefit to patiens, provides an extra 2-3 bed days to the hospital an provides savings of € 145.000,- .  

 

Nolan JP, reducing Catheter Related Bacteraemia in Haemodialysis. Vascular Access Soc. 5th Int. Congress of Vascular Access  Soc, Nice, 2007

 

Anti Coagulant

 

cl3046 afb 3

 1. Ash SR (2000) Concentrated Sodium Citrate (23%) for Catheter Lock. Haemodialysis International 4:22-31

 

Citra-Lock™ is based on higly concentrated trisodium citrate that prevents clotting and therefore helps maintaining  high flow rates whilst greatly reducing the need for Urokinase/tPA and otheter replacements.

 

Anti Biofilm

 

Trisodium citrate (TSC) lowers infection rates by reducing biofilm formation in hemodialysis catheters. The study of Bosma (2009) demonstrates an in vivo reduction of intraluminal catheter biofilm formation and bacterial colonizasion with the use of TSC 30% for HD catheter locking. By this mechanism, prevention of catheter-related infections by TSC can be largely explained.

 

Increase Safety & Simplified handling 

 

The Citra-Lock™ vial features a drip free Luer-Slip/Luer-Lock connector:luer slip lock

  • preventing microbial contamination
  • protecting against needle stick injuries
  • reducing handling steps
  • promoting intuitive handing

 

 Box 46

Download References  / Publications Citra-Lock™ 

 

Citra-Lock™ 46,7%  5ml vial

Boxes contain 20 x 5ml vial

Art.nr. 24060202

Œ1275











Citra-LockTM is trisodium citrate solution for catheter locking available from Renalfarma in following concentrations:

  • Citra-LockTM 4% 5ml vial
  • Citra-LockTM 30% 5ml vial
  • Citra-LockTM 46,7% 5ml vial
  • CitraFlowTM 4% prefilled syringe 2,5ml

     

    In addition to anti-clotting effect Citra-LockTM provides anti-microbial and anti-biofilm protection and does not have heparin side effects.


    Citra-LockTM and Citra-FlowTM are registered as a medical device (Class IIb)


  • New European Guidelines Catheter Lock Solution

    In the June edition of NDTplus the new European recommendation of preventing heamodialysis catheters by ERBP is published.
    ERBP ( European Renal Best Practice) is the new guidance body of the European Renal Association-European Dialysis and Transplantation Association (ERA-EDTA).

    The ERBP recommends to use Citrate lock of minimal 4% as the catheter lock solution instead of heparin.

    'The clinical advantages offered by citrate have been
    confirmed in at least two meta-analyses Over
    time, progressively lower concentrations of citrate have
    been applied (from 46.7% to 4%) with still significantly
    better results, even in the latter case, than those obtained with heparin locks
    1' .


    1. Vanholder et al, Diagnosis, prevention and treatment of haemodialysis catheter-related blood stream infections (CRBSI), a position statement of European Renal Best Practice (ERBP). NDTplus June 2010 

    Tags: 责任编辑:admin
    】【打印繁体】【投稿】【收藏】 【推荐】【举报】【评论】 【关闭】 【返回顶部
    分享到QQ空间
    分享到: 
    上一篇TRETTEN(重组凝血因子XIII A亚基.. 下一篇TRETTEN(重组凝血因子XIII A亚基..

    相关栏目

    最新文章

    图片主题

    热门文章

    推荐文章

    相关文章

    广告位