ves correlation of the diameter obtained in the disk test with the MIC for tigecycline. Reports from the laboratory providing results of the standard single-disk susceptibility test with a 15 mcg tigecycline disk should be interpreted according to the criteria in Table 4.
Anaerobic susceptibility testing with tigecycline should be done by the agar dilution method since quality control parameters for broth-dilution are not established.
A report of “Susceptible” indicates that the pathogen is likely to be inhibited if the antimicrobial compound reaches the concentrations usually achievable. A report of “Intermediate” indicates that the result should be considered equivocal, and, if the microorganism is not fully susceptible to alternative, clinically feasible drugs, the test should be repeated. This category implies possible clinical applicability in body sites where the drug is physiologically concentrated or in situations where high dosage of drug can be used. This category also provides a buffer zone that prevents small uncontrolled technical factors from causing major discrepancies in interpretation. A report of “Resistant” indicates that the pathogen is not likely to be inhibited if the antimicrobial compound reaches the concentrations usually achievable; other therapy should be selected.
Table 4. Susceptibility Test Result Interpretive Criteria for Tigecycline Manufacturer
Wyeth Pharmaceuticals Company, a subsidiary of Pfizer Inc.
Active Ingredients
Source
U.S. National Library of Medicine
DailyMed
Last Updated: 2nd of March 2011 |