f treatment with EXTRANEAL during the long dwell exchange, there were no differences in membrane transport characteristics for urea and creatinine. The mass transfer area coefficients (MTAC) for urea, creatinine, and glucose at one year were not different in patients receiving treatment with EXTRANEAL or 2.5% dextrose solution for the long dwell.
INDICATIONS AND USAGE
EXTRANEAL is indicated for a single daily exchange for the long (8- to 16- hour) dwell during continuous ambulatory peritoneal dialysis (CAPD) or automated peritoneal dialysis (APD) for the management of end-stage renal disease. EXTRANEAL is also indicated to improve (compared to 4.25% dextrose) long-dwell ultrafiltration and clearance of creatinine and urea nitrogen in patients with high average or greater transport characteristics, as defined using the peritoneal equilibration test (PET). (See CLINICAL PHARMACOLOGY, Clinical Studies)
CONTRAINDICATIONS
EXTRANEAL (icodextrin) is contraindicated in patients with a known allergy to cornstarch or icodextrin, in patients with maltose or isomaltose intolerance, in patients with glycogen storage disease, and in patients with pre-existing severe lactic acidosis.
WARNINGS
Dangerous Drug-Device Interaction (see BOXED WARNING)
Only use glucose-specific monitors and test strips to measure blood glucose levels in patients using EXTRANEAL (icodextrin) Peritoneal Dialysis Solution. Blood glucose monitoring devices using glucose dehydrogenase pyrroloquinolinequinone (GDH-PQQ) or glucose-dye-oxidoreductase (GDO)-based methods must not be used. Use of GDH-PQQ or GDO-based glucose monitors and test strips has resulted in falsely elevated glucose readings (due to the presence of maltose, see PRECAUTIONS/Drug/Laboratory Test Interactions) and has led patients or health care providers to withhold treatment of hypoglycemia or to administer insulin inappropriately. Both of these situations have resulted in unrecognized hypoglycemia, which has led to loss of consciousness, coma, permanent neurological damage, and death. Plasma levels of EXTRANEAL (icodextrin) and its metabolites return to baseline within approximately 14 days following cessation of EXTRANEAL (icodextrin) administration. Therefore falsely elevated glucose levels may be measured up to two weeks following cessation of EXTRANEAL (icodextrin) therapy when GDH-PQQ or GDO-based blood glucose monitors and test strips are used.
Because GDH-PQQ and GDO-based blood glucose monitors may be used in hospital settings, it is important that the health care providers of peritoneal dialysis patients using EXTRANEAL (icodextrin) carefully review the product information of the blood glucose testing system, including that of test strips, to determine if the system is appropriate for use with EXTRANEAL (icodextrin).
To avoid improper insulin administration, educate patients to alert health care providers of this interaction whenever they are admitted to the hospital.
Information regarding glucose monitor and test strip methodology can be obtained from their manufacturers. For a list of toll free numbers for glucose monitor and test strip manufacturers, please contact the Baxter Renal Clinical Help Line 1-888-RENAL-HELP or visit www.glucosesafety.com.
Not for intravenous injection.
Encapsulating peritoneal sclerosis (EPS) is a known, rare complication of peritoneal dialysis therapy. EPS has been reported in patients us